Accessories
Cat. No. Description
F-PE Pneumatic/Electric Switch. Factory set at 10 psig (69 kPa) to
“make” on pressure drop. May be field wired to “break” on
pressure drop. Pressure set point adjustable to 30 psig
(207 kPa).
F-R2 (24V) Time Delay Relay. 45-60 seconds to close when energized.
F-R12 (120V) Uses 120V or 24V power supply from remote source.
F-TBF T-Bar Frame Kit.
FF-SM Surface Mounting Frame for surface installations.
Painted White.
F-T1 Single pole built-in thermostat kit.
FF-T2 Double pole built-in thermostat kit.
F-TR4 208/240V Primary Transformer/24V Sec. and 24V Holding
Coil Control Relay.
F-TR7 277V Primary Transformer/24V Sec. and 24V Holding Coil
Control Relay.
Installation of Recessed Mounted
Heater in Plaster Ceiling
1. Determine the desired mounting location of the heater.
2. Cut a 14-1/2 inch (368mm) by 18-3/8 inch (467mm) hole in
the ceiling for the recessed back box, maintain 12 inch
(305mm) minimum distance between edge of hole and adja-
cent wall.
WARNING
THIS INSTRUCTION SHEET CONTAINS VITAL INFORMATION
FOR THE PROPER INSTALLATION, USE, AND EFFICIENT
OPERATION OF THE HEATER. CAREFULLY READ THE MANU-
AL BEFORE INSTALLATION, OPERATION, OR CLEANING OF
THE HEATER. FAILURE TO ADHERE TO THE INSTRUCTIONS
COULD RESULT IN FIRE, ELECTRICAL SHOCK, DEATH, SERI-
OUS PERSONAL INJURY OR PROPERTY DAMAGE. SAVE
THESE INSTRUCTIONS AND REVIEW FREQUENTLY FOR CON-
TINUING SAFE OPERATION AND INSTRUCTING FUTURE
USERS.
1. To prevent a possible electrical shock, disconnect all power
coming to heater at main service panel before wiring or ser-
vicing.
2. All wiring must be in accordance with the National and Local
Electrical Codes and the heater must be grounded as a pre-
caution against possible electrical shock.
3. Verify the power supply voltage coming to the heater match-
es the ratings printed on the heater nameplate before energiz-
ing.
4. Do not install the heater closer than 12 inches (305mm) to
any wall.
5. Do not operate heater without front cover installed.
6. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces.
7. Do not insert or allow foreign objects to enter any ventilation
or exhaust openings as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intakes or exhaust
in any manner. Keep combustible materials, such as boxes,
crates, etc., away from heater.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint or flammable liquids are
used or stored.
10. Use this heater only as described in this manual. Any other
use not recommenced by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is not approved for use in corrosive atmospheres
such as marine, green house or chemical storage areas.
Specifications
Cat. No. Volts Watts BTU/Hr. Amps
F-1500 120 1500 51,195 12.5
F-2008 208 2000 6826 9.8
F-2004 240/208 2000/1500 6826/5120 8.3/7.2
F-2007 277/240 2000/1500 6826/5120 7.2/8.2
F-1507 277 1500 5120 5.4
F-4008 208 4000 13,652 19.2
F-4004 240/208 4000/3000 13,652/10,239 16.7/14.4
F-4007 277/240 4000/3000 13,652/10,239 14.4/12.5
F-3007 277 3000 10,239 10.8
F-4804 240/208 4800/3600 16,382/12,287 20.0/17.3
F-4807 277/240 4800/3600 16,382/12,287 17.3/15.0
CONTRACTOR
PLEASE READ AND FOLLOW THESE INSTRUC-
TIONS. LEAVE INSTALLATION INSTRUCTIONS
FOR USER TO READ.
FAN DELAY NOTE: A fan delay is standard on all units. In order to
have the fan delay operate correctly, separate wiring is required
between the heater and the wall thermostat. See warning, page 2.
RISK OF FIRE - DO NOT INSTALL HEATER CLOSER THAN 12
INCHES (305mm) FROM ANY WALL.
RISK OF FALLING - THE HEATER BACK BOX MUST BE
SECURELY MOUNTED TO THE BUILDING STRUCTURE AND
THE BUILDING STRUCTURE MUST BE CAPABLE OF SUP-
PORTING THE HEATER WITH ALL ACCESSORIES. THE
HEATER WEIGHT IS AT LEAST 20 POUNDS (9 kg).
WARNING
Installation Instructions
and
RENEWAL PARTS IDENTIFICATION
“F” Series
Ceiling Mounted Fan-Forced Heater
1
FILE #E21609
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - “F” Series

AccessoriesCat. No. DescriptionF-PE Pneumatic/Electric Switch. Factory set at 10 psig (69 kPa) to “make” on pressure drop. May be field wired to “brea

Pagina 2 - Using the Cat. No. F-TBF Kit

3. Bring the power supply cable to the heater location providingat least 12 inches (305mm) of cable for wiring.4. Remove front cover and heater assemb

Pagina 3 - Renewal Part Indentificaiton

Heater Check-Out and Operation1. Turn the thermostat that is provided to control the heater tothe full counter-clockwise direction (LO or OFF setting)

Pagina 4 - LIMITED WARRANTY

LIMITED WARRANTYAll products covered by this instruction sheet are warranted against defects in workmanship and materials for one year from date of in