WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a rep-
utable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power
to heater circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is provided with a an automatic safety limit con-
trol that shuts the heater off should it overheat. If you find
the heater off, inspect for any objects on or adjacent to the
heater that may have blocked the airflow or otherwise
caused high temperatures to have occurred and remove any
objects that may have caused the overheating. Refer to the
Maintenance Instructions section of this manual for how to
reset this safety control.
12. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
13. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
14. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
!
Installation, Operation & Maintenance Instructions
WARNING
ECR 40234 08/14 5200-11217-002
IMPORTANT INSTRUCTIONS
COS-E Series
Fan-Forced Wall Heaters
MODEL MODEL VOLTS WATTS/AMPS WATTS/AMPS*
CZ1512T CZ1512-IF 120 1500W/12.5A 750W/6.3A
CZ1012T CZ1012-IF 120 1000W/8.4A 750W/4.2A
CZ1548T CZ1548-IF
240 1500W/6.3A 750W/3.1A
208 1125W/5.4A 563W/2.7A
CZ1048T CZ1048-IF
240 1000W/6.3A 500W/2.1A
208 750W/3.6A 375W/1.8A
CZ2048T CZ2048-IF
240 2000W/8.3A 1000W/4.2A
208 1500W/7.2A 750W/3.6A
Table 1. Specifications
* Factory wired for full wattage, field convertible to half wattage.
*-IF Models provided without back box or thermostat. Model CZBB Back-box and Model CZTDP thermostat kit sold separately.
CLIP-N-FIT
®
FEATURE
Patented CLIP-N-FIT
®
feature (US Patented
#6,172,343) allows installer to pick a
wattage onsite. Factory wired for full
wattage, easily field adjustable for half
wattage. Half wattage option is permanent
change complying with many local electrical
code requirements.
Conforms to ANSI/UL2021 and
CSA C22.2, No. 46
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - COS-E Series

WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THERISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-SONS, INCLUD

Pagina 2 - INSTALLATION

INSTRUCTIONS D'INSTALLATIONLes modèles avec un suffixe –IF ne sont pas fournis avec unboîtier arrière. Ces modèles sont prévus pour être utilisés

Pagina 3 - OPERATING

Installation et câblage d’ensemble radiateur / ventilateurREMARQUE: Pour des installations à une altitude dépassant 7 500pieds (2 286 m) au-dessus du

Pagina 4 - MAINTENANCE

123. Rétablissez l’alimentation électrique en amont, remettez le thermostat au point de consigne voulu, et vérifiez le bon fonctionnement du radiateur

Pagina 5 - Serie COS-E

2INSTALLATIONINSTRUCTIONSModels with -IF suffix are not provided with a back-box. Thesemodels are intended for use with Marley Model CZBB back-boxsol

Pagina 6 - INSTALACIÓN

Installation and Wiring of Heater / Fan AssemblyNOTE: For installations over 7500 ft. above sea level we recom-mend using heaters with wattages under

Pagina 7 - INSTRUCCIONES DE USO

3. Turn circuit breaker on, reset thermostat to desired setpoint,and verify the heater is operating normally.4. If the heater malfunctions again and s

Pagina 8 - MANTENIMIENTO

CUANDO SE UTILIZAN APARATOS ELÉCTRICOS, SIEMPREDEBEN SEGUIRSE PRECAUCIONES BÁSICAS PARA REDUCIR ELRIESGO DE INCENDIO, DESCARGAS ELÉCTRICAS Y LESIONES

Pagina 9 - Série COS-E

INSTRUCCIONES DEINSTALACIÓNNOTA: si la superficie de la pared Los modelos con sufijo -IF no se sum-inistran con caja posterior. Estos modelos son para

Pagina 10 - D'INSTALLATION

NOTA: los calefactores vienen cableados de fábrica de acuerdo a lapotencia y el voltaje indicados en su placa de identificación. Vea másdetalles en la

Pagina 11 - D’UTILISATION

3. Encienda el interruptor automático del circuito de alimentación, gireel termostato al punto de ajuste deseado y verifique que el calefactorfuncione

Pagina 12 - D’ENTRETIEN

LORS DE L’UTILISATION D’APPAREILS ÉLECTRIQUES, DES PRÉCAUTIONS DE BASE DOIVENT TOUJOURS ÊTRE SUIVIESAFIN DE RÉDUIRE LE RISQUE DE DÉPART D'INCENDI