Qmark CFWF - Counterflow Electric Wall Furnace Manuale Utente

Navigare online o scaricare Manuale Utente per Radiatori Qmark CFWF - Counterflow Electric Wall Furnace. Qmark CFWF - Counterflow Electric Wall Furnace User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 32
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Electric Counterflow
Wall Furnace
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered
Products. You have made a wise investment selecting the highest quality product in the heating indus-
try. Please carefully read the installation and maintenance directions shown in this manual. You should
enjoy years of efficient heating comfort with this product from Marley Engineered Products... the indus-
try’s leader in design, manufacturing, quality, and service.
... The Employees of
Marley Engineered Products
Installation & Maintenance Instructions
Read Carefully - These instructions are written to help
you prevent difficulties that might arise during installation
of your heaters. Studying the instructions first may save
you considerable time and money later. Observe the fol-
lowing procedures, and cut your installation time to a min-
imum.
TO REDUCE RISK OF FIRE OR ELECTRICAL SHOCK:
1. Disconnect all power coming to heater at main service
panel before wiring or servicing.
2. All wiring must be in accordance with the National and
Local Electrical Codes and the heater must be ground-
ed.
3. Verify the power supply voltage coming to heater
matches the ratings printed on the heater nameplate
before energizing.
4. This heater is hot when in use. To avoid burns, do not
let bare skin touch hot surfaces.
5. Do not insert or allow foreign objects to enter any ven-
tilation or exhaust opening as this may cause an elec-
tric shock, fire,or damage to the heater.
6. Do not block air intakes or exhaust in any manner.
Keep combustible materials, such as crates, drapes,
etc., away from heater. Do not install behind doors,
furniture, towels, or boxes.
7. A heater has hot and arcing or sparking parts inside.
Do not use it in areas where gasoline, paint, or flam-
mable liquids are used or stored.
8. Use this heater only as described in this manual. Any
other use not recommended by the manufacturer may
cause fire, electric shock, or injury to persons.
9. This heater is not approved for use in corrosive atmos-
pheres such as marine, green house, or chemical stor-
age areas.
10. Do not install this heater in an alcove.
11. Do not install this heater in a travel trailer or recre-
ational vehicle.
SAVE THESE INSTRUCTIONS
WARNING
!
Model # Voltage Watts Amps BTU/Hr.
CFWF920 240V 9.2kW 38 31,395
Vedere la pagina 0
1 2 3 4 5 6 ... 31 32

Sommario

Pagina 1 - Wall Furnace

Electric CounterflowWall FurnaceDear Owner,Congratulations! Thank you for purchasing this new heater manufactured by Marley EngineeredProducts. You ha

Pagina 2 - Optional Accessories

10PARTS LIST FOR CFWF920ITEM DESCRIPTION PART NUMBER1 OUTER CASING 2701-2033-0002 TOP FRONT PANEL 1402-2312-0003 BOTTOM FRONT PANEL 1402-2313-0004 TOP

Pagina 3 - Recessed Mount Installation

Generador eléctrico de airecaliente de retrocirculación,de pared.Estimado propietario:,Felicitaciones! Gracias por comprar este nuevo calentador fabri

Pagina 4 - Figure 5

Descripción del CFWF920Su generador eléctrico de aire caliente de retrocirculación, depared, se envía ensamblado para instalar en cualquier pared.Pued

Pagina 5 - Thermostat Installation

Cómo instalar su generador de paredPara asegurar una instalación apropiada y una operación segurade su Generador de Contracirculación, de Pared, siga

Pagina 6 - Mounting Your Furnace

Nota: SI LOS CENTROS DE LOS MONTANTES VERTICALESNO ESTAN SEPARADOS POR 16 PULGADAS (406 mm), VEAEL CIERRE DE LA DISTANCIA ENTRE MONTANTES VERTI-CALES

Pagina 7

Fig. 5. En algunos cielorasos altos la distancia desde el tope delcorte a la placa de pared del cieloraso puede ser mayor de 18 pul-gadas (457 mm). De

Pagina 8 - Operating Your Furnace

Montaje del Termostato1. Lea las instrucciones para el termostato. Sujete la cubierta deltermostato y tire suavemente de ella hacia afuera por su part

Pagina 9 - Danger of Bodily Injury

Instalación de la salida posterior opcionalGenerador de montaje empotrado1. Corte un orificio de 8-1/4 de pulgada (210 mm) x 12-1/4 pul-gadas (311 mm)

Pagina 10 - Bennettsville, SC 29512 USA

Alimentación de corriente eléctricaSu Generador de Contracirculación, de Pared, requiere un circuitode 240 voltios, 60 ciclos, 40 amperios de un inter

Pagina 11 - ADVERTENCIA

Como cuidar su generadorCuidado anual1.Elemento térmico y salida posterior opcionalMantenga limpio en todo momento. Use un cepillo suave o aspi-radora

Pagina 12 - Accesorios opcionales

CFWF920 DescriptionYour Counterflow Wall Furnace is shipped assembled forinstallation on any wall. It may be recessed up to 5-3/8inches (137 mm) with

Pagina 14

20LISTA DE PIEZAS PARA EL CFWF920ART. DESCRIPCION NO. DE PIEZA1 BASTIDOR EXTERNO 2701-2033-0002 PANEL DELANTERO SUPERIOR 1402-2312-0003 PANEL DELANTER

Pagina 15

N° de modèle Tension Watts A BTU/hCFWF920 240V 9,2kW 38 31,395Radiateur mural àcontrecourantCher utilisateur,Félicitations ! Nous vous remercions d&ap

Pagina 16 - (Montaje de superficie)

Description du radiateur CFWF920Votre radiateur mural à contre-courant est expédié entièrementassemblé, prêt à être installé contre un mur. Il peut êt

Pagina 17

Installation de votre radiateur muralPour que votre radiateur mural à contre-courant soit bien installéet fonctionne en toute sécurité, suivez attenti

Pagina 18

Remarque : SI LES PIECES DE COLOMBAGE NE SONT PASESPACEES DE 16 POUCES ENTRE LEURS CENTRES,REPORTEZ-VOUS A « REDUCTION DE LʼESPACE ENTRE LESPIECES DE

Pagina 19

Lorsque le plafond est haut, il est possible que lʼespace entre lehaut de lʼouverture et la sablière soit supérieure à 18 pouces (457mm). Dans ce cas,

Pagina 20

1. Lire les instructions fournies avec le thermostat. Prendre lecouvercle du thermostat et le tirer doucement vers lʼextérieurpour lʼenlever.2. Connec

Pagina 21 - Part No. 5200-2484-006

Installation de lʼévacuation arrière optionnelleRadiateur encastré1. Dans le mur, percez un trou de 8 1/4 po (210 mm) x 12 1/4 po(311 mm), comme dans

Pagina 22 - Radiateur mural à

Votre radiateur mural à contre-courant a besoin dʼun courant de 40ampères et 60 cycles sous 240 volts, protégé par un fusible ou undisjoncteur séparé

Pagina 23 - Accessoires optionnels

How to Install Your Wall FurnaceFollow the directions carefully to ensure proper installa-tion and safe operation of your Counterflow Wall Furnace.All

Pagina 24 - ! ATTENTION !

Entretien de votre radiateurNettoyage annuel1. Élément chauffant et évacuation arrière optionnelleCes composants doivent toujours demeurer propres. Ut

Pagina 26

30LISTE DE PIÈCES DU RADIATEUR CFWF920CODE DESCRIPTION N° DE PIÈCE1 BOÎTIER EXTÉRIEUR 2701-2033-0002 PANNEAU SUPÉRIEUR AVANT 1402-2312-0003 PANNEAU IN

Pagina 27 - Figure 9

Note: IF STUDS ARE NOT ON 16-INCH (406 mm) CEN-TERS, SEE CLOSE OFF STUD SPACE ON PAGE 4 AND5.Cut Wall OpeningsRefer to Figure 3. Lay out and cut the r

Pagina 28 - Danger de dommages

In some high ceilings the distance from the top of thecutout to the ceiling wall plate may be more than 18 inch-es (457 mm). If so, we recommend that

Pagina 29

Mounting the Thermostat1. Read instructions for thermostat. Grasp thermostatcover and pull gently outward at top to remove.2. Connect the thermostat w

Pagina 30

Optional Rear Outlet InstallationRecessed Mount Furnace1. Cut 8-1/4 inch (210 mm) x 12-1/4 (311 mm) inch holein wall as shown in Fig. 3, page 4.2. The

Pagina 31

Electric Power SupplyYour Counterflow Wall Furnace requires a 240-volt, 60cycle, 40-ampere circuit from a separate circuit breaker orfuse in your serv

Pagina 32

How to Take Care of Your FurnaceAnnual Upkeep1. Heating Element and Optional RearOutletKeep clean at all times. Use a soft brush or vacuumcleaner to c