Ceiling Mounted
Fan Forced Heater
SERIES 500
Read Carefully - These instructions are written to help you
prevent difficulties that might arise during installation of
heaters. Studying the instructions first may save you consid-
erable time and money later. Observe the following proce-
dures and cut your installation time to a minimum.
1. TO REDUCE THE RISK OF FIRE OR ELECTRIC
SHOCK, disconnect all power coming to heater at main
service panel before wiring or servicing.
2. All wiring must be in accordance with the National and
Local Electrical Codes and the heater must be grounded
as a precaution against possible electric shock.
3. Verify the power supply voltage coming to heater match-
es the ratings printed on the heater nameplate before
energizing.
4. This heater is intended for ceiling installation ONLY.
Do not install the heater closer than 12” (305mm) to any
wall for models 548, 542, 547 and 24” (610mm) to any
wall for models 558, 552 and 557.
5. Do not insert or allow foreign objects to enter any ventila-
tion or exhaust opening.
6. Do not block air intakes or exhaust in any manner. Keep
combustible materials, such as crates, drapes, etc., away
from heater.
7. A heater has hot and arcing (sparking) parts inside. Do
not use it in areas where gasoline, paint, or flammable
liquids are stored.
8. This heater is not approved for use in corrosive atmos-
pheres such as marine, green house, or chemical storage
areas.
9. The heater enclosure must be securely mounted to ceil-
ing or framing capable of supporting the heater (45 lbs /
20.4 kg). Failure to do so could allow heater to fall.
10. Do not operate heater without outlet grilles installed.
When installing grilles with louver guides, make sure
guides drop into position so they cannot slide out during
use.
WARNING
SAVE THESE INSTRUCTIONS
!
Dear Owner,
Congratulations! Thank you for purchasing this new heater manufactured by Marley Engineered
Products. You have made a wise investment selecting the highest quality product in the heating indus-
try. Please carefully read the installation and maintenance directions shown in this manual. You should
enjoy years of efficient heating comfort with this product from Marley Engineered Products... the indus-
try’s leader in design, manufacturing, quality and service.
... The Employees of
Marley Engineered Products
Installation & Maintenance Instructions
1
Recessed Mount
Surface Mount
Vedere la pagina 0
1 2 3 4 5 6

Sommario

Pagina 1 - SERIES 500

Ceiling MountedFan Forced HeaterSERIES 500Read Carefully - These instructions are written to help youprevent difficulties that might arise during inst

Pagina 2 - IMPORTANT

IMPORTANT NOTICE - This heater is wired so the fan will comeon with no delay when energized as the thermostat is calling forheat. When the thermostat

Pagina 3 - HEATER IN T-BAR CEILING

6. Position the surface mounting plate against the ceilingand secure with bolts or screws (Figure 2). SeeWarning No. 9. Connect the ground wire to the

Pagina 4 - HEATER IN PLASTER CEILING

16. Run the power supply cable through the connector, leav-ing about 8” (203mm) of wire inside the recess mountingbox. (Power supply cable must be #10

Pagina 5

17. With the recess face plate seated firmly against theheater section, depress the “thumb pins”. This willcause the thumb pins to expand and will tem

Pagina 6 - IMPORTANT INFORMATION

LIMITED WARRANTYAll products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from d