Description
Specifications and Performance
INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL
MODELS: E3606-1125HFD, E3609-1125HFD, E3612-1125HFD
E3806-1125HFD, E3809-1125HFD, E3812-1125HFD
E4206-1125HFD, E4209-1125HFD, E4212-1125HFD
E4806-1125HFD, E4809-1125HFD, E4812-1125HFD
E6006-2125HFD, E6009-2125HFD, E6012-2125HFD
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE
PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY
DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
REFER TO INDIVIDUAL MODEL NUMBERS
FOR UNIT WIDTH
11
7
/
8
3
1
/
4
15
3
/
4
12
1
/
2
Figure 1
Heated Air Curtains
MODEL HEATER MOTOR HEATER HEATER HEATER CFM AT NOZZLE MOTOR
NUMBER VOLTAGE VOLTAGE WATTS BTU/HR AMPS (HI/LOW) SIZE
E3606-1125HFD 240/1 120 6000 20,478 25.0 2025/1500 1/4HP
E3609-1125HFD 240/1 120 9000 30,717 37.5 2025/1500 1/4HP
E3612-1125HFD 240/1 120 10,800 36,860 45.0 2025/1500 1/4HP
E4806-1125HFD 240/1 120 6,000 20,470 25.0 2700/2000 1/4HP
E4809-1125HFD 240/1 120 9,000 30,717 37.5 2700/2000 1/4HP
E4812-1125HFD 240/1 120 10,800 36,860 45.0 2700/2000 1/4HP
E6006-2125HFD 240/1 120 6000 20,478 25.0 3375/2500 1/4HP
E6009-2125HFD 240/1 120 9000 30,717 37.5 3375/2500 1/4HP
E6012-2125HFD 240/1 120 10,800 36,860 45.0 3375/2500 1/4HP
Note: For multiple unit installations, recommended spacing between units should be a minimum of 3-inches and a maximum of 6-inches.
Unit is allowed to extend beyond doorway width. Each unit must have individual power supply.
Air curtains produce a wall of continuously flowing air
that acts as a thermal barrier against outside air and
provides protection against insects, dust, odor, fumes
and other contaminant’s and maintains interior
conditioned temperature by preventing heated or
cooled air from escaping through open doorways.
Heated air curtains are engineered to treat incoming
cold air at customers’ entrance areas. Used over front
door entrances, heated air curtains supplement existing
heat to prevent infiltration of colder outside air. Heated
units are not recommended for areas subject to high
winds.
Figure 2 Dimensions
Note that all dimensions are the same on all environmental
series units. Model number indicates width of unit.
(Example: E4800 indicates a 48” wide unit.)
Vedere la pagina 0
1 2 3 4 5 6 7 8

Sommario

Pagina 1 - Heated Air Curtains

DescriptionSpecifications and PerformanceINSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUALMODELS: E3606-1125HFD, E3609-1125HFD, E3612-1125H

Pagina 2 - Unpacking

25. Carefully disconnect motor electric cord and heaterplug assembly and remove two wing nuts on blowerbase. (See Figure 4.)Figure 4 - Remo

Pagina 3 - Installation

Installation1. Using template provided, determine mountinglocation.2. Drill holes and attach mounting hardware (notincluded).IMPORTANT: THE

Pagina 4 - Maintenance

Operation1. After power has been connected to unit, fans will startin either preset (high/low) speed selection.2. Air velocity is controlled by select

Pagina 5 - Troubleshooting Chart

Troubleshooting ChartSYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTIONFan inoperative1. Blown fuse or open circuit breaker.2. Electricity turned off.3. Loos

Pagina 6 - Figure 8 - Replacement Parts

Replacement Parts For Motor Blower Assemblies (7)6Replacement Parts For Heater Units1.245631412111315891016Replacement Parts For Air Curtain Cabinets9

Pagina 7 - NO. 6 KW 9 KW 10.8 KW QTY

Replacement Parts List For Air Curtain CabinetsReplacement Parts For 120 Volt Single Phase Motor Blower AssembliesReplacement Parts List For Heater Un

Pagina 8 - LIMITED WARRANTY

8HOW TO ORDER REPAIR PARTSIn order to obtain any needed repair orreplacement parts, warranty service or technicalinformation, please con

Commenti su questo manuale

Nessun commento