Qmark Ceiling Fan Accessories Manuale Utente

Navigare online o scaricare Manuale Utente per Ventole Qmark Ceiling Fan Accessories. Qmark Ceiling Fan Accessories User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 4
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
®
A Marley Engineered Products Brand
ASSEMBLY INSTRUCTIONS & PARTS MANUAL
CEILING FAN GUARDS
MODELS: 2800-1 AND 2800-2
Description
The Leading Edge ceiling fan guards are designed to be
used with Leading Edge Commercial/Industrial ceiling
fans. This guard is strongly recommended for use on
fans located in any area where there is a possibility of
objects larger than 3” being thrown into the fan. This
ceiling fan guard is suited for school gymnasiums,
indoor arenas and other public areas. Each unit
consists of 8 (eight) sections, guard, clamp, brace, and
assembly hardware. The guard has a galvanized finish.
General Safety Information
NOTE: Ceiling fan guards to be used in conjunction
with specified fan models only: 52” guard - 3620-1,
4820-1, and 62” guard - 5600-1LC, 5631-1R, 5610-1,
5600-1, 5601-1, 5600-7, 6000-1, 6001-1, 6010-1.
1. Care should be taken to ensure that power source to
fan is locked off before guard is installed so that the
fan creates no hazard to installer.
2. Make sure hanger hooks are mounted securely to
structural ceiling members and must support 150
pound load limit.
3. Make sure guard is securely in place before placing
fan into operation.
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE, OR MAINTAIN THE PRODUCT
DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO
COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Maintenance
WARNING: MAKE CERTAIN THAT THE POWER
SOURCE IS DISCONNECTED BEFORE ATTEMPTING
TO SERVICE OR DISASSEMBLE ANY COMPONENTS!
IF THE POWER DISCONNECT IS OUT OF SIGHT,
LOCK IT IN OPEN POSITION AND TAG TO PREVENT
APPLICATION OF POWER.
CLEANING
This fan guard may be wiped off with a damp cloth. If
already installed on ceiling fan, do not allow the fan
motor to get wet. Do not use solvents or harsh
detergents.
Figure 1
Dimensions
MODEL
NUMBER
DIMENSIONS
AB
2800-1
2800-2
62”
52” 10
3
/
4
10
3
/
4
Figure 2
Vedere la pagina 0
1 2 3 4

Sommario

Pagina 1 - CEILING FAN GUARDS

®A Marley Engineered Products BrandASSEMBLY INSTRUCTIONS & PARTS MANUALCEILING FAN GUARDSMODELS: 2800-1 AND 2800-2DescriptionThe Leading Edge ceil

Pagina 2 - IMPORTANT!

1. Place three guard bottom sections on flat surface(floor) and connect together in 3/4circle usingenclosed 11/8” bolts, washers, lockwashers and 5/16

Pagina 3

Figure 7 - Hang Fan & GuardFigure 9 - Attach “Secondary Support Cable”6. Install last quarter section of fan guard as in itemtwo above and attach

Pagina 4 - Replacement parts List

Figure 11 - Replacement Parts IllustrationReplacement parts ListREF.NO. DESCRIPTIONPART NO. QTY.11A23456789101112131415Quarter Section 62”Quarter Sect

Commenti su questo manuale

Nessun commento